Blue etchant instructions
1. Each bag weighs 200g ± 10g, as per the weight 1:4 adding the water
2. You can use a plastic storage box or porcelain basin as a container for the configuration solution. Do not use a metal basin.
3. In order to ensure the use effect, the temperature during etching is preferably at least 50 degrees. Therefore, the water can be heated to 100 degrees before the etchant is placed. After the etchant is dissolved, the circuit board to be etched is placed, and the container is continuously stirred during the etching, and if the operation is correct, and the etching can be completed within 5-15 minutes.
4. The solution is a clear and blue clear liquid, which will not bring yellow pollution that is difficult to remove like ferric chloride. The etching process is clearly visible and the highest precision can be easily achieved.
5. The old liquid remaining after the first etching can be reserved for the second use, and the new liquid could be changed when the effect is deteriorated.
6. Although the etchant itself is harmless, it will contain copper ions in the waste liquid, which will pollute the environment. Therefore, it is best to treat it with alkaline substances such as alkali or lime before disposal. And properly protect the environment is protect yourself
IPC-HDBK-830 Etching Agent
200g
- N/A
More from this Category
ZVS Low Voltage Induction Heating Power Supply with Induction Coil (5-12V)
0.28" Mini Digital Voltmeter & Ammeter (DC 100V 10A, Blue and Red Dual LED Display)
Mini ZVS Induction Heating DIY Kit (12V, 150W)
FG-100 DDS Function Signal Generator (1Hz-500KHz)
21L Vacuum Chamber and Pump (RS-1, Single-Stage Rotary Vane Vacuum Pump, 21L Chamber, Stainless Steel)
PCB Portable Photosensitive Dry Film (15CMx2M)
1Hz-65KHz LCD 1602 DDS Function Signal Generator